Safety Installation Guidelines for Underground Electrical Conduits

July 14, 2022

When excavating, one of the dangers that are most likely to occur is an injury to an underground electrical wire. The following illustrations illustrate some of the most common ways in which humans come into contact with live electrical wires. Make sure that you have all of the appropriate precautions under your belt before commencing any excavation. Follow these instructions to put the conduit in the ground in a way that is secure and will endure for a long time. Engineering projects and even those carried out at home might profit from them.

Check the Bottom Soil

It's not over yet once you've excavated the trench for your conduits; there are other things to accomplish. As a first step, check to see that your trench is clean of debris. Your conduits might be damaged by any harsh thing. Water can enter a conduit with as little as a micro-fracture. If water penetrates your conduit, it will then seep through the cable jacket's extremely small pinholes. As a result of the cable shield becoming saturated, corrosion will occur. As a result, the insulated cable's resistance rises. As a result, the overall cable losses will rise and you'll get a weak signal. The conductor's insulation will be soaked if water gets into your coaxial wire. Increasing cable losses will cause you to lose all of your signals. To finish the trench, be careful to compress the soil and level it out. Each segment of conduit you instal should have the same amount of bearing and support. Because backfilling a trench with dirt that has varying elevations might put additional strain on a conduit. There will be damage to the conduit and water penetration difficulties as a result of this.

Finally, ensure that your excavation area is dry during construction. Static water levels should be lowered at least 2 feet below the bottom of excavations to prevent damage to the foundation. Soils will remain in their native form, unaltered. It'll also make it possible to properly put any sturdy fill.

Temperature Matters

Conduits should be installed below the frost level in extremely cold places. Any water that gets into your conduit won't freeze if you do this. The conduit is also protected from thermal expansion and contraction. The installation may not be feasible if your frost depth is more than 8 feet below grade. In these cases, the first step is to verify with your local government. Installing a snow blower in a chilly area is likely to have specific instructions. However, don't give up if you don't get any useful input.  In the area you've excavated, put a layer of hard insulation on top of the conduit. This will assist to keep the soil from becoming too cold and causing more damage. Insulation of one inch rigid is a good illustration of this. This layer of protection is equivalent to one foot of normal soil. The 1-inch thick insulation should be installed at the 4-foot point if your frost line is 5 feet below grade.

Observe Social Distancing, Too!

Moulded plastic spacers should be installed every six feet when using more than one conduit. A 3-inch gap between the conduits is also recommended. Conduits are less likely to droop and distort as a result. You'll also be able to retain the current-carrying capability of your conductors, which is important for power conduits. As a bonus, you'll eliminate hot spots on your cables by maintaining a consistent impedance. Your wire's insulation will eventually be damaged by hot spots. This can lead to ground faulting difficulties, which can be dangerous. Use spacers if you're stacking your conduits vertically with flowable fill and you're utilising spacers. Self-compacting, cement-like substance, flowable fill, is utilised in place of compact fill. You may condense your conduits around them with the use of spacers. In addition, you'll keep your conduits from dangling throughout the concreting phase.

Proper Backfill is Important

The proper backfilling of conduits is essential. Because tiny and large rocks are commonly found in your native dug dirt. As we previously explained, you don't want your conduit to come into contact with any hazardous materials. Grains that are devoid of organic materials are ideal. The sand equivalent value of the material should not be less than 20. Backfilling materials should be non-expansive, have a plasticity index below 8, have a liquid limit below 30, and include less than 3.5 per cent organic material.